Untitled Document
 

 
 
Wheel Alignment
¤ýMirage 10000RF
¤ýTSCT-750L
Wheel Balance
¤ýTSB900B
¤ýTSB950
¤ýTSB950A
¤ýTSB1900A
¤ýTSB-Bench
Tire Changer
¤ýTSC920
¤ýTSC990A
¤ýTSC990A + HF200
Exhaust Gas Analyzer
¤ýTS bench & BLUE-I bench
¤ýExhaust gas analyzer
¤ýMobile emissions inspector
Smoke Tester
¤ýTDST-301
¤ýTSOM-1000
RPM Meter
¤ýBlue-I R-1000
Refrigement Leak Detector
¤ýAG-3000
 




  • TS Sensor Bench & BLUE-I bench / Exhaust gas analyzer
    TS sensor bench
    BLUE-I bench

  • 4GAS analyzer bench(5gas Available)
  • 4gas (Non-dispersive infrared inhalation method) (NDIR method)
  • Lightweight size and weight maintenance
  • CO, HC, CO2, (O2, Nox optional)
  • Easy to assemble and check the quality of the environment, adapting products.
    Exhaust Gas Analyzer (GAS BENCH) Specifications
Item Specificatons
Model TS sensor bench, BLUE-I bench
Measurement items CO,HC,CO2,O2,Excess air ratio,AFR,Nox(Optional)
Measurement principles CO,HC,CO2:NDIR
O2,nox:Electric Formula
Range CO: HC: Co2: O2:
0-10% Vol 0-9999 0~20% 0~25%
¡¡ ppm Vol Vol
Graduations CO:0.01% HC:1ppm Co2:0.1% O2:0.01%
Repeatability 2%/F.S
O2 sensor life 1 year
Show the way Digital
Calibration method Zero Calibration: automatic calibration method
Span Calibration: span gas automatic calibration method using
HC Span Gas Set the rate Propane x 0.498
Response rate 10 seconds to 90% response
Warm-up time I'm re-energized in the case of 10 minutes 5 minutes climate
Pump flow 1.8L/min
Environment Temperature:-10~40, Humidity 90% Below
Printer Features option
Transfer Status option
Power Ac 220V 50/60Hz
Size 130X30X30
Weight 1.4kg
    Feature
  • Separate each measurement without complicated procedures without having to press the button for automatic continuous measurement can be
  • a built-in pressure sensor probe and the tube can check the status of the leak, and can tell when to replace the filter.
  • Measurement sample cells and each part is equipped with sensors to detect the temperature and constant temperature control system to maintain constant temperature and
    Is managed at all times to provide a certain measure.
  • built-in auto-purge function measured within 30 minutes of a fuzzy measure if it does not exist to conduct ecological and atmospheric measurements
    Switches.
  • Automatic zero adjustment function is built into the base always tells the correct measure.
  • The printer features built-in by default always easy measurement results can be printed.
  • PC monitor, a computer program can be used in conjunction with. (OPTIONAL)

Untitled Document
 
 
Untitled Document
  Head office: 605, Samho bldg, 34-11, Haan 2-dong, Gwangmyeong-si, Gyeonggi-do, Korea
TEL:+82-2-807-3283    FAX:+82-2-809-3283
Factory: 191-4 Mokgam-dong Siheung-si Gyeanggi-do Korea